MENUMENU
- Valves
- Flow
Control - Pressure
Measurement - Temperature
Measurement - Electronic
Interface - Manufacture and
Modification
V250 Pressure Switch w / Overpressure Protection
Company Name : Wasco
Activation Point Range:
- 0.5 – 29.5 inHg
Burst Pressure:
- 6,000 PSI
Temperature Range:
- -65° F to + 225° F
Leak Rate:
- ≤1.0 x 10-3 cc/min Air
Weight:
- 5 oz (typical with 12 inch “W3” electrical interface)
Electrical Rating :
Max. Amp Rating | 1 | 5 | 7 |
---|---|---|---|
Volts AC/DC | 115/28 | 250/28 | 250/28 |
Inductive | |||
Amp Resistive | 1/1 | 5/5 | 7/7 |
Amp Material | 1/0.5 | 5/3 | 7/4 |
Contact | Gold | Silver | Silver |
Technical Specifications
Material Specifications V250:
Wetted
Diaphragm | Kapton® or Stainless Steel |
Fitting | 300 Series Stainless Steel |
O-Ring | Buna N, other compounds available |
Screw | 300 Series Stainless Steel |
Washer | 300 Series Stainless Steel |
Material Specifications V250:
Non Wetted
Actuator/Springs | Steel |
Adjusting Nut | Steel |
Body | 300 Series Stainless Steel |
Electrical Interface | Steel (zinc chromate finish) |
Locking Compound | Loctite 277 |
Vacuum Switch Adjustment (if field adjustable)
A change in the activation may be made by turning the adjusting ring located in the opening in the side of the body. Causing the ring to turn right will raise the activation point, and left will lower it. For the best results after resetting the switch, cycle the system pressure level several times to stabilize the new activation point. Repeat preceding adjustment instructions if necessary.