000124

Flow monitors and Flow indicators in full metal version

 DUM
 Flow monitor for liquids

Operation:
The flow monitors type DUM operate with the float measuring principle.

  000124
Specification:    
000548 for liquids (0,2 – 250 l/min) 000544 Operating temperature max.:
100°C (opt. 160°C)
000549 Operating pressure max.:
PN 200 bar (brass)
PN 300 (st. st.)
000446 any orientation
any flow direction
001120 Switch contact: Normally open or change over (optional) 000445 EX-proof to ATEX (optional)
000444 UL-certified (optional) pdf

Data Sheet >>

Manual >>

   
The flow monitors type DUM operate with the float measuring principle.  
  • wide switch range
  • sturdy construction
  • high operating pressure
  • installation in any orientation

 DUM/A
 Flow monitor and indicator for liquids

Operation:
The flow monitors and indicators type DUM/A operate with the float measuring principle.

  000126
Specification:    
000548 for liquids (0,2 – 250 l/min) 000544 Operating temperature max.:
100°C (opt. 160°C)
000549 Operating pressure max.:
PN 200 bar (brass)
PN 300 (st. st.)
000723 mechanical display 000446 any orientation
any flow direction
001120 Switch contact: Normally open or change over (optional)
000445 EX-proof to ATEX (optional) 000444 UL-certified (optional) pdf

Data Sheet >>

Manual >>

The flow monitors and indicators type DUM/A operate with the float measuring principle.  
  • wide measuring range
  • sturdy construction
  • high operating pressure
  • installation in any orientation

 DWM
 Flow monitor for liquids

Operation:
The flow monitors type DWM operate with the float measuring principle.

  000134
Specification:    
000563 for liquids (0,1 – 50 l/min) 000541 Operating temperature max.:
100°C (opt. 160°C)
000549 Operating pressure max.:
PN 200 bar (brass)
PN 300 bar (st. st.)
000252 orientation vertical
flow direction bottom to top
001120 Switch contact: Normally open or change over (optional) 000445 EX-proof to ATEX (optional)
000444 UL-certified (optional) pdf

Data Sheet >>

Manual >>

   
The flow monitors type DWM operate with the float measuring principle.  
  • wide switch range
  • sturdy construction
  • high operating pressure
  • high switch accuracy

 DWM-L
 Flow monitor for gases

Operation:
The flow monitors type DWM-L operate with the float measuring principle.

  000134
Specification:    
001248 for gases (1 – 1450 Nl/min) 000569 Operating temperature max.:
80°C
000568 Operating pressure max.:
PN 200 bar (brass)
PN 300 (st. st.)
000252 orientation vertical
flow direction bottom to top
001120 Switch contact: Normally open or change over (optional) 000445 EX-proof to ATEX (optional)
pdf

Data Sheet >>

Manual >>

       
The flow monitors type DWM-L operate with the float measuring principle.  
  • wide switch range
  • sturdy construction
  • high operating pressure
  • high switch accuracy

 DWM/A
 Flow monitor and indicator for liquids

Operation:
The flow monitors and indicators type DWM/A operate with the float measuring principle.

  000136
Specification:    
000563 for liquids (0,1 – 50 l/min) 000541 Operating temperature max.:
100°C (opt. 160°C)
000568 Operating pressure max.:
PN 200 bar (brass)
PN 300 bar (st. st.)
000723 mechanical display 001120 Switch contact: Normally open or change over (optional) 000252 orientation vertical
flow direction bottom to top
000445 EX-proof to ATEX (optional) 000444 UL-certified (optional) pdf

Data Sheet >>

Manual >>

The flow monitors and indicators type DWM/A operate with the float measuring principle.  
  • wide measuring range
  • sturdy construction
  • high operating pressure
  • high switch accuracy

 DWM/A-L
 Flow monitor and indicator for gases

Operation:
The flow monitors and indicators type DWM/A-L operate with the float measuring principle.

  000136
Specification:    
001247 for gases (1 – 1450 Nl/min) 000569 Operating temperature max.:
80°C
000568 Operating pressure max.:
PN 200 bar (brass)
PN 300 bar (st. st.)
000723 mechanical display 001120 Switch contact: Normally open or change over (optional) 000252 orientation vertical
flow direction bottom to top
000445 EX-proof to ATEX (optional) pdf

Data Sheet>>

Manual >>

   
The flow monitors and indicators type DWM/A-L operate with the float measuring principle.  
  • wide measuring range
  • sturdy construction
  • high operating pressure
  • high switch accuracy

 M-21
 
Flowmeter for liquids and gases

Operation:
The M-21 flowmeters operate on the float measuring principle. A valve for flow regulation is available as an option.

  000174
Specification:    
000620 for liquids
(0,1 – 1000 l/h)
000617 for gases
(4 – 30000 Nl/h)
000619 Operating temperature max.:
180°C (with electronic)
210°C (without electronic)
000618 Operating pressure max.:
PN 16 bar (with NV)
PN 40 bar (without NV
000252 orientation vertical
flow direction bottom to top
000255 Switch contact: Change over
000723 mechanical display 000728 Analog output pdf

Data Sheet >>

Manual >>

The flow monitors and indicators type RVO/U operate on the float measuring principle.  
  • small physical size
  • sturdy construction
  • installation in any orientation

 RMU-A
 Flow monitor for liquids

Operation:
The flow monitors type RMU-A operate with the float measuring principle.

  000188
Specification:    
000733 for liquids
(2,5 – 15,5 l/min)
000732 Operating temperature max.:
120°C (opt. 160°C)
000731 Operating pressure max.:
PN 250 bar
000446 any orientation
any flow direction
000725 Switch contact: Normally open pdf

Data Sheet >>

Manual >>

The flow monitors type RMU-A operate with the float measuring principle.  
  • small physical size
  • sturdy construction
  • low sensivity to dirt

 RMU-B
 Flow monitor for liquids

Operation:
The flow monitors type RMU-B operate with the float measuring principle.

  000190
Specification:    
000746

for liquids
(0,4 – 18,5 l/min)

000659 Operating temperature max.:
100°C (opt. 160°C)
000731 Operating pressure max.:
PN 250 bar
000446 any orientation
any flow direction
000725 Switch contact: Normally open pdf

Data Sheet >>

Manual >>

The flow monitors type RMU-B operate with the float measuring principle.  
  • small physical size
  • sturdy construction
  • low sensivity to dirt

 RVM/U-1
 
Flow monitor for liquids

Operation:
The flow monitors type RVM/U-1 operate with the float measuring principle.

  001185
Specification:    
001209 for liquids
(10 – 150 l/min)
000662 Operating temperature max.:
100°C (opt. 160°C)
000738 Operating pressure max.:
PN 250 bar (brass)
PN 300 bar (st. st.)
000446 any orientation
any flow direction
001120 Switch contact: Normally open or change over (optional) 000445 EX-proof to ATEX (optional)
 
    pdf

Data Sheet >>

Manual >>

The flow monitors type RVM/U-1 operate with the float measuring principle.  
  • small physical size
  • sturdy construction
  • installation in any orientation

 RVM/U-2
 Flow monitor for liquids

Operation:
The flow monitors type RVM/U-2 operate with the float measuring principle.

  000194
Specification:    
000639 for liquids (0,02 – 30 l/min) 000553 Operating temperature max.:
100°C (opt. 160°C)
000637 Operating pressure max.:
PN 300 bar (brass)
PN 350 bar (st. st.)
000446 any orientation
any flow direction
001120 Switch contact: Normally open or change over (optional) 000445 EX-proof to ATEX (optional)
000444 UL-certified (optional) pdf

Data Sheet >>

Manual >>

   
The flow monitors type RVM/U-2 operate with the float measuring principle.  
  • small physical size
  • sturdy construction
  • installation in any orientation

 RVM/U-4
 Flow monitor for liquids

Operation:
The flow monitors type RVM/U-4 operate with the float measuring principle.

  000196
Specification:    
000642 for liquids (0,005 – 5 l/min) 000544 Operating temperature max.:
100°C (opt. 160°C)
000640 Operating pressure max.:
PN 300 bar (brass)
PN 350 bar (st. st.)
000446 any orientation
any flow direction
001120 Switch contact: Normally open or change over (optional) 000444 UL-certified (optional)
pdf

Data Sheet >>

Manual >>

       
The flow monitors type RVM/U-4 operate with the float measuring principle.  
  • small physical size
  • sturdy construction
  • installation in any orientation

 RVM/U-L1
 Flow monitor for gases

Operation:
The flow monitors type RVM/U-L1 operate with the float measuring principle.

  001187
Specification:    
000646 for gases (60 – 650 Nl/min) 000544 Operating temperature max.:
120°C (opt. 160°C)
000647 Operating pressure max.:
PN 250 bar (brass)
PN 300 bar (st. st.)
000446 any orientation
any flow direction
001120 Switch contact: Normally open or change over (optional) 000445 EX-proof to ATEX (optional)
000444 UL-certified (optional) pdf

Data Sheet >>

Manual >>

   
The flow monitors type RVM/U-L1 operate with the float measuring principle.  
  • small physical size
  • sturdy construction
  • installation in any orientation

 RVM/U-L2
 Flow monitor for gases

Operation:
The flow monitors type RVM/U-L2 operate with the float measuring principle.

  000200
Specification:    
000649 for gases (2,5 – 525 Nl/min) 000651 Operating temperature max.:
120°C (opt. 160°C)
000650 Operating pressure max.:
PN 300 bar (brass)
PN 350 bar (st. st.)
000446

any orientation
any flow direction

001120 Switch contact: Normally open or change over (optional) 000445 EX-proof to ATEX (optional)
000444 UL-certified (optional) pdf

Data Sheet >>

Manual >>

   
The flow monitors type RVM/U-L2 operate with the float measuring principle.  
  • small physical size
  • sturdy construction
  • installation in any orientation

 RVM/U-L4
 Flow monitor for gases

Operation:
The flow monitors type RVM/U-L4 operate with the float measuring principle.

  000202
Specification:    
000652 for gases (0,6 – 80 Nl/min) 000654 Operating temperature max.:
120°C (opt. 160°C)
000650 Operating pressure max.:
PN 300 bar (brass)
PN 350 bar (st. st.)
000446 any orientation
any flow direction
001120 Switch contact: Normally open or change over (optional) 000444 UL-certified (optional)
pdf

Data Sheet >>

Manual >>

       
The flow monitors type RVM/U-L4 operate with the float measuring principle.  
  • small physical size
  • sturdy construction
  • installation in any orientation

 RVM/U-S4
 Flow monitor for liquids

Operation:
The flow monitors type RVM/U-S4 operate with the float measuring principle.

  000207
Specification:    
000747 for liquids
(0,005 – 5,0 l/min)
000541 Operating temperature max.:
100°C (opt. 160°C)
000650 Operating pressure max.:
PN 300 bar (brass)
PN 350 bar (st. st.)
000446 any orientation
any flow direction
000725 Switch contact: Normally open 000444 UL-certified (optional)
pdf

Data Sheet >>

       
The flow monitors type RVM/U-S4 operate with the float measuring principle.  
  • high pressure resistance
  • high reliability
  • high switch accuracy
  • installation in any orientation

 RVM/UA-1
 Flow monitor for liquids

Operation:
The flow monitors type RVM/UA-1 operate with the float measuring principle.

  000136
Specification:    
001230 for liquids
(10 – 150 l/min)
000938 Operating temperature max.:
100°C (opt. 160°C)
000937 Operating pressure max.:
PN 250 bar (brass)
PN 300 bar (st. st.)
000723 mechanical display 001120 Switch contact: Normally open or change over (optional) 000446 any orientation
any flow direction
000445 EX-proof to ATEX (optional)     pdf

Data Sheet>>

Manual >>

The flow monitors type RVM/UA-1 operate with the float measuring principle.  
  • small physical size
  • sturdy construction
  • installation in any orientation

 RVM/UA-2
 
Flow monitor for liquids

Operation:
The flow monitors type RVM/UA-2 operate with the float measuring principle.

  000934
Specification:    
000939 for liquids (0,02 – 30 l/min) 000940 Operating temperature max.:
100°C (opt. 160°C)
000941 Operating pressure max.:
PN 300 bar (brass)
PN 350 bar (st. st.)
000446 any orientation
any flow direction
001120 Switch contact: Normally open or change over (optional) 000445 EX-proof to ATEX (optional)
000723 mechanical display pdf

Data Sheet >>

Manual >>

   
The flow monitors type RVM/UA-2 operate with the float measuring principle.  
  • small physical size
  • sturdy construction
  • installation in any orientation

 RVM/UM
 Flow monitor for liquids

Operation:
The flow monitors type RMU-A operate with the float measuring principle.

  000204
Specification:    
000751 for liquids
(0,1 – 120 l/min)
000752 Operating temperature max.:
100°C (opt. 160°C)
000753 Operating pressure max.:
PN 250 bar (brass)
PN 300 bar (st. st.)
000252 orientation vertical
flow direction bottom to top
001120 Switch contact: Normally open 000445 EX-proof to ATEX (optional)
000444 UL-certified (optional) pdf

Data Sheet >>

Manual >>

   
The flow monitors type RVM/UM operate with the float measuring principle.  
  • low switchpoint at high flowrate
  • sturdy construction
  • installation in any orientation

 SC-250
 Flowmeter for liquids and gases

Operation:
The instruments, type SC-250, are variable area flowmeter.

  000223
Specification:    
000682 for liquids
(2,5 – 180000 l/h)
000679 for gases
(0,1 – 5400 Nm³/h)
000681 Operating temperature max.:
200°C (opt. 400°C)
000680 Operating pressure max.:
PN 10 bar / PN 16 bar / PN 40 bar
000723 mechanical display 000252 orientation vertical
flow direction bottom to top
000255 Switch contact: Change over (optional) 000447 Output: 4 – 20 mA (optional) 000445
EX-proof to ATEX
(optional, analog output only)
pdf

Data Sheet >>

       
The instruments, type SC-250, are variable area flowmeter.  
  • high accuracy
  • product specific scale
  • nominal size up to DN 150
  • several options

 WBM-65
 
Flow monitor for liquids

Operation:
The flow monitors type WBM-65 operate with the float measuring principle.

  000975
Specification:    
000978 for liquids
(6 – 23 m³/h)
000977 Operating temperature max.:
100°C (opt. 160°C)
000976 Operating pressure max.:
PN 16 bar
000446 any orientation
any flow direction
001120 Switch contact: Normally open or change over (optional) 000445 EX-proof to ATEX (optional)
 
    pdf

Data Sheet >>

The flow monitors type WBM-65 operate with the float measuring principle.  
  • Flange-connection
  • high reliability
  • installation in any orientation

 WBMC
 Flow monitor for liquids

Operation:
The flow monitors type WBMC operate with the float measuring principle.

  001122
Specification:    
001125 for liquids (8 – 22 m³/h) 001316 Operating temperature max.:
100°C (opt. 160°C)
001315 Operating pressure max.:
PN 180 bar (st. st.)
000446 any orientation
any flow direction
001120 Switch contact: Normally open or change over (optional) 000445 EX-proof to ATEX (optional)
pdf Data Sheet >>        
The flow monitors type WBMC operate with the float measuring principle.  
  • universal orientation
  • hihge reliabiliy
  • thread-connection

 

Request a Callback

Please Leave a message and we will get back to you the next business day.




    [mathcaptcha mathcaptcha-779]